This instructional video demonstrates a Quartz Sleeve and Germicidal UV Lamp removal and replacement for a Bio-Logic® UV Water Purifier.
Bio-Logic® UV Water Purifier Lamp Removal
SAFETY EQUIPMENT REQUIRED TO PERFORM TASK
Step 1
WARNING: Disconnect power to the Bio-Logic® UV Water Purifier
Step 2
Remove EASY-OFF™ End Cap by pulling cap off static gland nut. Slide end cap along the wire away from the socket.
Step 3
Carefully withdraw lamp approximately 2 inches from chamber to reveal lamp socket.
Step 4
While holding lamp end, carefully remove lamp socket on end now exposed.
Step 5
Carefully remove lamp from chamber. Be sure to withdraw lamp straight out without angling until completely clear of quartz sleeve.
CAUTION: Lamp and quartz sleeve are easily damaged. Exercise care when handling.
Bio-Logic® UV Water Purifier Quartz Sleeve Removal
Step 1
Remove the other EASY-OFF™ End Cap by pulling cap off static gland nut.
Step 2
Unscrew static gland nut from end of the chamber. Avoid striking quartz sleeve with static gland nut.
Step 3
Remove Teflon® washer from end of quartz sleeve. Teflon® washer will sometimes remain within the static gland nut.
Step 4
Remove O-Ring from end of quartz sleeve.
Step 5
Unscrew static gland nut from end of the chamber. Avoid striking quartz sleeve with static gland nut.
Step 6
Remove Teflon® washer from end of quartz sleeve. Teflon® washer will sometimes remain within the static gland nut.
Step 7
Remove O-Ring from end of quartz sleeve.
Step 8
Carefully remove quartz sleeve from chamber. NOTE: It is advisable to support the quartz sleeve on the opposite end with your finger so that it does not drop to the bottom of the chamber as it slides into the chamber.
Bio-Logic® UV Water Purifier Quartz Sleeve Installation
Step 1
Carefully slide quartz sleeve through chamber. Make sure the quartz sleeve protrudes an equal distance past each threaded nipple.
Step 2
Affix O-Ring to quartz sleeve.
Step 3
Affix Teflon® washer to quartz sleeve.
Step 4
Screw on gland nut, DO NOT USE HAND TOOLS. Tightening with hand tools is likely to cause quartz sleeve to break.
Step 5
Attach EASY-OFF™ End Cap to static gland nut.
Step 6
Affix O-Ring to quartz sleeve.
Step 7
Affix Teflon® washer to quartz sleeve.
Step 8
Screw on gland nut, DO NOT USE HAND TOOLS. Tightening with hand tools is likely to cause quartz sleeve to break.
Bio-Logic® UV Water Purifier Lamp Installation
Step 1
Carefully slide lamp through chamber straight without angling.
Step 2
Connect socket to end of lamp.
Step 3
Attach EASY-OFF™ End Cap to static gland nut.
For more information on the Bio-Logic® UV Water Purifier, visit our Bio-Logic® Overview Page or download the Owner’s Manual.